SKU 01 Classic 50W
50 W, IP54 / IP65, mounting height 4 to 10 m.
- Power 50 W
- Luminous flux up to 9,000 lm
- Ingress protection IP54 / IP65
515,200 UZS
incl. 12% VAT
Open the model
100 W, IP54 / IP65, mounting height 4 to 10 m.
940,800 UZS
Price includes 12% VAT. Price list dated 30 March 2026.
2018 photometry taken from the HLT model of the same name. A new report is in progress.
A bracket-mounted street luminaire for roads, plant driveways, car parks and fuel station forecourts. Twice the flux of Classic 50W lets you widen the pole spacing. On short spans it is more than you need.
| Power | 100 W |
|---|---|
| Luminous flux, calculated | up to 18,000 lm 1 |
| Luminous efficacy, calculated | up to 180 lm/W 2 |
| Ingress protection | IP54 / IP65 |
| Colour temperatures | 3000 / 4000 / 6500 K |
| Beam angle | 113° at half of peak intensity 6 see the curve |
| Mounting height | 4 to 10 m |
| Ambient temperature | -30 to +50 °C 3 |
| Rated life | 50,000 h (L90), calculated 4 |
| Warranty | 3 years |
| Housing | Extruded aluminium profile |
| SKU | sku-01-classic-100 |
| Colour rendering index Ra | Details are being confirmed 5 |
| Percent flicker | Details are being confirmed 5 |
| Unified glare rating UGR | Details are being confirmed 5 |
| Supply voltage range | Details are being confirmed 5 |
| Dimensions | Details are being confirmed 5 |
| LEDs and driver | Details are being confirmed 5 |
Built from the same IES file that is available for download. There is a problem with this file; it is described right below the curve.
We do not show the numbers from this file. Its curve integrates to 45,409 lm while the stated flux is 13,000 lm, a factor of 3,5. A luminaire does not emit more than is put into it, so one of the two numbers in the file is wrong, and the file itself does not say which. The shape of the curve is usable, the absolute values are not: this file must not go into a calculation until the manufacturer issues a corrected one.
C0-C180 C90-C270
The file is dated 2018 and comes from the HLT model of the same name. The calculated flux in the table above was obtained differently. The file was recorded at 5700 K while the model ships in 3000 / 4000 / 6500 K: module flux depends on colour temperature and has to be recalculated for another one.
2018 photometry taken from the HLT model of the same name. A new report is in progress. This file does not agree with itself: the site does not show numbers from it, and the explanation is under the curve on the model page.
One data sheet per model, 11 files.
Mandatory for HS 9405 (Cabinet of Ministers Resolution No. 43, annex 4, item 107). Being reissued; the number and validity will be shown here.
11 models across four series, unit prices.
Same optics and hardware, different power.
Send your technical specifications or floor plan: an engineer works out the illuminance in DIALux, the number of luminaires and the payback period.