IES file viewer

Drop any IES file here, ours or someone else's. The browser draws the light distribution curve, computes the flux from the curve itself, compares it with the flux stated in the file and shows what the luminaire delivers on the floor. Nothing is uploaded: the whole analysis runs on your device.

IES file

File A

Drop a file into this area, pick one from disk or paste the file text. Formats: IES (every LM-63 edition) and LDT (EULUMDAT).

Paste the file text

What is in the file

Intensity by angle

Heat map of the table in the file: azimuth C across, angle from nadir down. The denser the colour, the more candelas.

Isolux plot on the floor

Illuminance from one luminaire on a horizontal plane: E = I(C, γ) · cos³γ / h² / Kz. Grid in metres, labels in lux. Direct component only, no reflections.

Photometric solid

The same table in three dimensions: the distance from the centre to the surface is proportional to the intensity in that direction. Rotate it to see the asymmetry between planes.

Room illuminance estimate

How many lux this luminaire gives in a rectangular room. Only the direct component is computed: light that arrives straight from the luminaire, with no reflections from walls or ceiling and no maintenance factor.

Why this is here

The photometric file is the one document a lighting designer uses to calculate your site. It carries two numbers for flux: the one written in the header and the one its own curve produces. When they disagree, the DIALux calculation comes out wrong, and you find out after the installation.

We ran this code over our own seven files, found two unusable ones and removed their numbers from the site. The same code sits here so you can check any file, ours or anyone else's.

What is not computed: UGR (it needs the room geometry and the observer position), type A and B photometry (floodlights and vehicle lamps), tilt from an external TILT file.